Accredited calibration, turn-key EMC test systems and expert consulting, delivered by one local team so your lab stays compliant without the complexity.
Medical devices, IEC 60601-1-2NSG 4070C-LFCP with LAS loopsSee the system →
EV and components, ISO 7637, LV 124VDS 200Q battery simulatorSee the bench →
On-site EMC testing, IEC 61000-4-6NSG 4070C with KEMZ 801B clampSee the kit →
High-voltage DC power, ISO 21498-2Ripple NX ripple generatorSee the system →
Consumer products, CISPR 32 and 35NSG 6000A radiated immunity systemSee the system →
Whether you need a certificate next month, a new chamber next year, or advice today, ICX Lab covers the whole EMC lifecycle.
On-site calibration in Malaysia, Singapore and Vietnam under LAB Support Ltd.'s A2LA accredited ISO/IEC 17025 scope, performed by the LAB Support Southeast Asia team. ICX Lab is the authorised Southeast Asia sales representative.
Authorised distributor for AMETEK CTS, Frankonia EMC, Nexio and CHANGEN. From a single generator to a complete anechoic chamber, we design, supply, install and train.
Practical EMC guidance for manufacturers and test labs: which standards apply, how to set up a compliant test, and how to prepare your product before the formal test.
A sample of the generators, chambers, software and accessories we supply and support. Every item links to the full range.
ESD simulatorsIEC 61000-4-2, up to 30 kV
Surge and burst generatorsIEC 61000-4-4 / -4-5
RF immunity systemsIEC 61000-4-3 / -4-6
SAC-3 Plus chamber3 m semi-anechoic, CISPR 16-1-4
Turntables and mastsFTM turntables, FAM antenna masts
BAT-EMC softwareEmission and immunity automation
Fibre-optic transceiversLIN, CAN FD, Ethernet over fibre
Antenna standsLow-reflection tripods and fixtures
Your instruments are calibrated where they are used, under LAB Support Ltd.'s A2LA accredited ISO/IEC 17025 scope, by the LAB Support Southeast Asia team. Field calibration is written into the accredited scope, so a certificate issued in your laboratory carries the same accreditation as one issued in Japan.
Short technical notes on the standards our customers wrestle with, written by the engineers who run the equipment. Simulators and worked examples included.
What CISPR 16-1-2 and IEC 61000-4-6 actually ask a LISN, ISN or CDN calibration to measure, why a raw S21 is not a voltage division factor, the uncertainty terms a plain S-parameter uncertainty budget leaves out, and how to read a scope or a certificate in two minutes.
7 minute readWhat the free-space antenna factor is and how the standard site method obtains it, why emission testing uses it and nothing else, and why an antenna factor calibrated at 3 m or in vertical polarisation is not the more accurate one, with a visualiser of the error it adds to every emission result.
14 minute readEIRP and ERP, why a radio is judged by what it puts into the air, how the substitution method of ANSI and ETSI works step by step, and the clause that lets a verified site calibration replace it.
9 minute readWe reply within one working day with a quote or a plan.