Accredited calibration · RF components

Attenuator, cable, coupler and amplifier calibration to 40 GHz

S-parameters, insertion loss, return loss, coupling factor, directivity and amplifier gain of RF components calibrated on site under LAB Support Ltd.'s A2LA accredited ISO/IEC 17025 scope.

Why it matters

Cables and attenuators are corrections in every EMC measurement

Every radiated and conducted emission result subtracts a cable loss, and every immunity system relies on coupler and attenuator values to set forward power. These corrections drift with connector wear and cable flexing, so the components are calibrated on a schedule. All of them are covered under one S-parameter capability from 5 Hz to 40 GHz.

  • Insertion loss and return loss of cables, attenuators and adapters
  • Coupling factor and directivity of directional couplers
  • Amplifier and preamplifier gain and flatness
  • Adapters and transitions between connector families
ParameterRangeCommon methods and standards
Transmission S21/S12, magnitude and phase5 Hz to 40 GHzNetwork analyser with calibration kit
Reflection S11/S22, magnitude and phase, VSWR5 Hz to 40 GHzNetwork analyser with calibration kit
Attenuators and RF cables, insertion loss9 kHz to 40 GHzNetwork analyser, substitution
Directional couplers, coupling and directivity9 kHz to 40 GHzNetwork analyser
Amplifiers and preamplifiers, gain9 kHz to 40 GHzNetwork analyser, power meter

The methods and standards shown are the ones most commonly requested. Within each parameter and range listed on the accredited scope, other calibration methods and standard editions can be supported under the flexible-scope provisions of LAB Support's A2LA accreditation. The measurement uncertainty for each parameter is stated on the certificate. Field calibration is included in the scope for every line above.

Instruments we calibrate

Models we calibrate most often

From our own calibration records. Any instrument within the scope can be calibrated; these are the ones we see most.

Huber+Suhner Sucoflex cables Teseq INA 265B, ATN attenuators Werlatone, Narda directional couplers Keysight 87405C, 8449B preamplifiers Schwarzbeck BBV 9718 preamplifier AR, Teseq CBA, Bonn, Prana amplifiers and others
On site

How the visit runs

Send the listComponent models, connector types, frequency range and power rating.
We come to youThe team brings a calibrated network analyser, calibration kits for each connector family and reference attenuators.
Measure in placeS-parameters across the band at the points your corrections use, with the adapters you use.
Certificate on siteISO/IEC 17025 certificate with tabulated values and plots, uncertainty and traceability.
Frequently asked

Questions we are asked

Which connector families are covered?

N, SMA, 3.5 mm, 2.92 mm, 2.4 mm, BNC and 7/16 with the corresponding calibration kits. Tell us the connectors and adapters you use so the right kits come.

Can high-power amplifiers be calibrated in the system?

Yes. Amplifier gain and flatness are measured at the drive levels you use, and the coupler and power sensor in the same path are calibrated at the same visit.

Do you provide the cable loss table in the format my software needs?

The certificate tabulates insertion loss at the frequencies you specify. Data files for BAT-EMC, Compliance Test Studio and EMC32 correction tables can be supplied on request.

Which countries do you cover on site?

Malaysia, Singapore and Vietnam, with Penang as the base. Other locations on request.

Tell us what you need to test