Accredited calibration · Oscilloscopes

Oscilloscope calibration, amplitude, bandwidth and timebase, in your lab

Vertical amplitude accuracy, bandwidth, timebase and frequency accuracy and trigger sensitivity of oscilloscopes measured on site under LAB Support Ltd.'s A2LA accredited ISO/IEC 17025 scope, by the LAB Support Southeast Asia team.

Why it matters

Every transient generator certificate rests on an oscilloscope

Burst, surge, ESD and automotive pulse parameters are all measured with an oscilloscope, and the scope's own amplitude accuracy and bandwidth enter the uncertainty of each. A laboratory that calibrates its own generators, or verifies them between external calibrations, needs its oscilloscope on an accredited certificate. Bandwidth and rise time matter most for ESD and burst work.

  • Vertical amplitude accuracy into 50 ohm and 1 megohm
  • Bandwidth to 6 GHz and rise time
  • Timebase and frequency accuracy
  • Trigger sensitivity and probe compensation
ParameterRangeCommon methods and standards
Vertical amplitude, DC, 50 ohm input1 mV to 5 VDC reference, DMM
Vertical amplitude, DC, 1 megohm input1 mV to 25 VDC reference, DMM
Bandwidth and frequency response9 kHz to 6 GHzLevelled signal generator, power sensor
Timebase and frequency accuracy0.1 Hz to 6 GHzFrequency reference
Trigger sensitivity1 mV to 25 VSignal generator
Rise time0.5 ns and aboveFast-edge generator

The methods and standards shown are the ones most commonly requested. Within each parameter and range listed on the accredited scope, other calibration methods and standard editions can be supported under the flexible-scope provisions of LAB Support's A2LA accreditation. The measurement uncertainty for each parameter is stated on the certificate. Field calibration is included in the scope for every line above.

Instruments we calibrate

Models we calibrate most often

From our own calibration records. Any instrument within the scope can be calibrated; these are the ones we see most.

Keysight DSOX6002A, DSOX3000, InfiniiVision 4000 X Keysight Infiniium S-series Tektronix DPO4104B, MSO46, MSO68B Tektronix TBS1000, TDS3000 series Teledyne LeCroy WaveRunner, WaveSurfer, HDO Rohde & Schwarz RTB, RTM, RTO Rigol DS and MSO series and others
On site

How the visit runs

Send the listModel, number of channels, bandwidth and the probes you want included.
We come to youThe team brings a calibrated DC reference, levelled RF source, power sensor and frequency reference.
Measure in placeAmplitude at each range on each channel, bandwidth, timebase, trigger sensitivity and rise time.
Certificate on siteISO/IEC 17025 certificate with measured error per channel and range, uncertainty and traceability.
Frequently asked

Questions we are asked

Are all channels calibrated?

Yes, each channel at each vertical range in use. Tell us if some channels can be excluded to shorten the visit.

Can high-voltage and differential probes be included?

Yes. Probe attenuation and bandwidth are calibrated on the probe and clamp page's scope, in the same visit.

Does calibration include the manufacturer's self-calibration?

The oscilloscope's internal self-calibration is run before measurement where the manufacturer recommends it, then the instrument is measured against traceable references.

Which countries do you cover on site?

Malaysia, Singapore and Vietnam, with Penang as the base. Other locations on request.