EMC System Turn-Key Solutions

Complete EMC test systems, delivered as one project

ICX Lab is the authorised distributor for AMETEK Compliance Test Solutions, Frankonia, Nexio and CHANGEN. We specify, supply, install, commission and train, so you sign one contract and get a working laboratory.

Solutions

From a single generator to a full chamber

Every system is specified against the standards you need to test to, then built from products we support locally.

Generator burst, surge, ESD, RF pulse Coupling network CDN, clamp, probe onto the lines EUT Product under test Monitor pass / fail CONDUCTED IMMUNITY

Immunity test systems

ESD, EFT/burst, surge, dips and interruptions, conducted RF immunity and radiated immunity, with amplifiers, antennas and field monitoring.

  • IEC 61000-4-2 / -4 / -5 / -6 / -11
  • IEC 61000-4-3 radiated immunity
  • Harmonics and flicker, IEC 61000-3-2 / -3
EUT turntable 1 to 4 m antenna mast 3 or 10 m RF EMI receiver scan, peak search, final quasi-peak vs limit

Emission test systems

Conducted and radiated emission measurement with EMI receivers, LISNs, antennas, masts and turntables under automated control.

  • CISPR 11 / 14 / 22 / 32 and CISPR 25
  • FCC Part 15 and Part 18
  • Fully automated scan, peak search and final measurement
EUT 3 / 5 / 10 m Frankosorb absorbers on walls and ceiling conductive ground plane · shielded shell · door and gate

Chambers and shielded rooms

Semi-anechoic and fully anechoic chambers, shielded enclosures and reverberation chambers, engineered and installed by Frankonia.

  • 3 m, 5 m and 10 m test distances
  • Site validation to CISPR 16-1-4 and ANSI C63.25.1
  • Turntables, antenna masts and control
2 m vehicle on turntable, ISO 11451 / CISPR 25 ECU BCI component bench ISO 11452, ISO 7637

Automotive EMC

Component and vehicle-level test systems for OEM and CISPR 25 / ISO 11452 / ISO 7637 requirements, including transient generators and BCI.

EXISTING CHAMBER, UNCHANGED receiver, 2008generator, discontinuedsoftware, unsupported Before replace new EMI receivernew generatorsBAT-EMC software After then re-validate: NSA, SVSWR

Upgrades and retrofits

Replace ageing generators, receivers or software in an existing laboratory without rebuilding the chamber, and re-validate the site afterwards.

1234 Site surveyInstallCommissionTrain power, floor, accesschamber, equipmentvalidate, acceptoperators, procedures ICX Lab on site, with the manufacturer's engineers support TURN-KEY PROJECT

Installation, training and support

Site survey, installation, commissioning, operator training and after-sales support from engineers based in the region.

Our principals

Products we are authorised to sell and support

AMETEK Compliance Test Solutions

AMETEK Compliance Test Solutions

EMC immunity and emission test equipment from the EM TEST, Teseq and AR brands: transient and power-quality generators such as the compact NX and NSG 3040A, dito and NSG 438 ESD simulators, NSG 4070 and NSG 6000A RF immunity systems, CDNs, automotive transient and battery simulators, CBA and AR amplifiers, antennas and GTEM cells.

ESDEFT / BurstSurgeDipsHarmonics & FlickerRF immunityAutomotiveAmplifiersAntennasGTEM

See the AMETEK CTS range →

EM TEST
Teseq
AR
Frankonia

Frankonia

Anechoic chambers, shielded rooms, reverberation chambers and turn-key EMC laboratories from the German chamber builder founded in 1987: FAC-3 and SAC-3 chambers for 3 m, SAC-5 and SAC-10 for full compliance and vehicles, ACTC, AVTC and EDTC automotive chambers, MIL-STD chambers, Frankosorb absorbers, shielding and gates, FTM turntables and FAM antenna masts.

Anechoic chambersShielded roomsAutomotiveMIL-STDReverberationFrankosorb absorbersTurntablesAntenna masts

See the Frankonia range →

Nexio

Nexio

French EMC software specialist since 2003. BAT-EMC is hardware-independent test automation for emission and immunity, used by more than 600 laboratories in 25 countries, with drivers for over 500 instruments and two years of maintenance included. The range covers electrical transients (BAT-ELEC), radio spurious (BAT-RADIO), click rate (BAT-CLICK), site validation (BAT-NSA/SVSWR), metrology, EUT monitoring and the BAT-SCANNER near-field system.

Test automationEmissionImmunityCISPR 25Site validationEUT monitoringReporting

See the BAT-EMC range →

CHANGEN

CHANGEN

Laboratory accessories from Guangzhou, founded 2012: fibre-optic transceivers for LIN, CAN FD, automotive Ethernet and analogue signals, RF-over-fibre systems to 40 GHz, HD316 shielded cameras and HDB projectors, 9120 series antenna stands, low-dielectric test tables and fixtures, probes to OEM standards, dynamometers and consumables.

Optic transceiversRF over fibreShielded camerasAntenna standsLow-dielectric fixturesProbesDynamometers

See the CHANGEN range →

How a project runs

Turn-key means we own the outcome

ConsultWe map the standards, products and throughput you need to the right test distance, chamber and equipment.
Design and quoteSystem block diagram, equipment list, site requirements and a single commercial proposal.
Supply and installChamber construction, equipment delivery, cabling and integration managed on site by ICX Lab.
Commission and trainSite validation, acceptance tests, operator training and documentation ready for your accreditation file.

Tell us what you need to test

We reply within one working day with a quote or a plan.

Contact us