AR · 10 kW solid-state amplifier

AR 10000A225D

10 kW of Class A solid-state power from 10 kHz to 225 MHz, the band below the log-periodic antenna.

AR 10000A225D 10 kW solid-state amplifier
Key facts

AR 10000A225D at a glance

  • 10 000 W CW, 10 kHz to 225 MHz
  • Class A design with push-pull LDMOS output stages
  • 100 % mismatch tolerant
  • Touch screen digital control panel showing forward and reflected power
  • Forward and reflected RF sample ports, gain control and pulse input
  • Air cooled by self-contained fans, with internal liquid cooling
  • Remote control by Ethernet, USB, GPIB, fibre-optic serial and RS-232
  • Modular design for maintenance and service
  • US export classification EAR99

Figures from the manufacturer's product page. Specifications are subject to change; the datasheet governs. Quotations on request.

Where it fits

What the 10000A225D is used for

Below about 200 MHz a radiated immunity test uses E-field generators, striplines and large biconical or TEM devices, all of which present a poor match to the amplifier. The 10000A225D is the AR answer for MIL-STD-461 RS103 from 2 MHz, for whole-vehicle tests to ISO 11451-2 at the low end, and for high-level bulk current injection.

Which model a programme needs is a system design question, and at this power level the mains supply, cooling air and RF cabling are part of it. Send us your test plan and we will size the amplifier with the rest of the system.

Typical standards for this product

MIL-STD-461 RS103MIL-STD-461 CS114ISO 11451-2ISO 11451-4RTCA/DO-160 Section 20
Calibration

Calibrated on site, by the people who supplied it

Amplifiers, including AR models, are covered by our RF component calibration. High-power amplifiers are calibrated in the system, with the coupler and power sensor of the same path at the same visit. Calibration is carried out in your laboratory by the LAB Support Southeast Asia team, under the A2LA accredited ISO/IEC 17025 scope of LAB Support Ltd.

Related

Goes with the 10000A225D

Frequently asked

AR 10000A225D in Malaysia

What is the AR 10000A225D used for?

High-level RF immunity below 225 MHz: MIL-STD-461 RS103 from 2 MHz with E-field generators, the low end of whole-vehicle tests, and high-level bulk current injection.

Where can I buy the AR 10000A225D in Malaysia?

ICX Lab Services in Penang is the authorised distributor of AMETEK CTS products, and AR is one of the brands under AMETEK CTS, together with EM TEST and Teseq. Send us the model number through the contact page or WhatsApp and we reply with a configuration and a quotation. Quotations on request.

Who installs and supports the 10000A225D after delivery?

We do. ICX Lab handles delivery, installation and training, and coordinates factory service, firmware and repairs with AMETEK CTS on your behalf.

AR RF/Microwave Instrumentation is part of AMETEK Compliance Test Solutions. Product name, specifications and image are taken from ar.ametek-cts.com.

Need a quotation for the 10000A225D?

Tell us the standards you test to and we will configure it with the accessories it needs.

Request a quotation   All AR models

Tell us what you need to test

We reply within one working day with a quote or a plan.